The GE WR30X10061, WR30X10093 Ice Maker Assembly is the replacement Ice Maker for most GE Refrigerators that come with ice makers. Replaces mechanical, electro-mechanical, and electronic ice makers. The Appliance Repair website offers a free online GE refrigerator repair manual. In addition, the official GE website has owner’s manuals and installation instructions searchable by model number. Appliance Repair’s online repair manual is designed to help the amateur, do-it-yourself type repairperson diagnose and fix common malfunctions of. In this GE icemaker repair guide I will walk you through the steps in repairing your GE icemaker. GE has two style icemakers and they are old mechanical style and the newer electronic style. Refrigerator ice makers on sale - Whirlpool, Kenmore, GE and others. View and Download GE Monogram ZDIS150WSS technical service manual online. Under-the-Counter Icemaker. Monogram ZDIS150WSS Ice Maker pdf manual download. Also for: Monogram zdis150www, Monogram zdis150wbb. Ice Maker 15-Inch - Nugget Ice UNC15NJII. UNC15NJII is rated 4.7. 5 by rbattman from Everyone likes nugget ice Replaced and old icemaker and wife wanted a nugget ice maker. Researched them and found the GE model as the best available considering price and features. Our online tools are here 24 hours a day to help you arrange the service. Ge gss22jetaww ice maker manual - Refrigerators question. SOURCE: GE model GSH25JFTACC ice maker not working When an ice maker is producing ice poorly-when it produces just a few cubes or none, or when the cubes are too small-it's usually because of a clogged water line or a defective water inlet valve.
Work with state-of-the-art photography tools. Control color and tone. Process images professionally with the. Adobe photoshop 3.0 download free.
Related Articles
GE's Monogram label focuses on luxury features, industrial-grade design and eco-friendly energy usage. Among the lineup, a little over a half-dozen Monogram side-by-side refrigerators feature GE's water dispenser and icemaker with a built-in proximity sensor. High-end features aside, no appliance is flawless. If your Monogram's icemaker runs into trouble, there are troubleshooting procedures that apply to all of the label's 36-, 42- and 48-inch models, both built-in and freestanding.
Filters and Flow
If your icemaker seems sluggish or if it produces small or hollow cubes, a dirty filter may be inhibiting the flow of water to the device. Locate the cylinder-shaped water filter cartridge in the rear, upper-right corner of the refrigerator compartment. Slowly unscrew the filter cartridge from the cartridge holder and screw in a new filter cartridge -- either a SmartWater or Water by Culligan filter, for Monogram models -- by turning it clockwise until it clicks into the cartridge holder. After installing the filter, run about 1 1/2 gallons of water from the dispenser to prevent future water flow complications. For optimal ice and water production, GE recommends replacing the filter cartridge every six months.
Water Worries and Temperature Troubles
If the icemaker doesn't produce ice at all, ensure the valve on the water supply line connected to your refrigerator is fully open. A Monogram icemaker works best when the water pressure ranges from 40 to 120 psi. If ice production is too slow for your taste, set the freezer compartment to a lower temperature to encourage quicker ice making. A leaky dispenser may indicate cubes jammed in the chute. The manufacturer recommends freeing the cubes by poking the chute with a wooden spoon.
More Troubleshooting Measures
Don't overlook the simple stuff; make sure the power switch on your fridge's icemaker is set to the “On” position before moving on with troubleshooting. If the icemaker stops producing ice before the storage bin is full, check the bin for anything obstructing the feeler arm, which is the flat, blade-shaped appendage on the bottom of the icemaker. Clear any obstructions, including frozen-on ice cubes, to ensure the icemaker accurately detects when the bin is full. Level the ice in the bin and break up any irregular clumps.
Getting in Touch With GE
Monogram refrigerators sometimes require professional maintenance; if basic troubleshooting doesn't do the trick, schedule a service appointment via GE's official Monogram site or contact the GE Answer Center. In addition to scheduling service, you can contact GE to order new filter cartridges. If you register your new Monogram appliance at GE's site upon purchase, the company covers the refrigerator under a limited warranty that extends up to 12 years.
References (4)Resources (3)About the Author
Dan Ketchum has been a professional writer since 2003, with work appearing online and offline in Word Riot, Bazooka Magazine, Anemone Sidecar, Trails and more. Dan's diverse professional background spans from costume design and screenwriting to mixology, manual labor and video game industry publicity.
Photo Credits
Choose Citation Style
Ketchum, Dan. 'How to Troubleshoot a GE Monogram Icemaker.' Home Guides | SF Gate, http://homeguides.sfgate.com/troubleshoot-ge-monogram-icemaker-102591.html. Accessed 08 October 2019.
Ketchum, Dan. (n.d.). How to Troubleshoot a GE Monogram Icemaker. Home Guides | SF Gate. Retrieved from http://homeguides.sfgate.com/troubleshoot-ge-monogram-icemaker-102591.html
Ketchum, Dan. 'How to Troubleshoot a GE Monogram Icemaker' accessed October 08, 2019. http://homeguides.sfgate.com/troubleshoot-ge-monogram-icemaker-102591.html
Note: Depending on which text editor you're pasting into, you might have to add the italics to the site name.
A useful and handy diagnostic technique when working on an ice maker problem is to manually initiate a harvest cycle to see with the ice maker will or will not do. Here's how to manually cycle the GE WR30X10093 ice maker:
Power On Diagnostics
When the icemaker is first connected to power and if thermistor temperature is 50°F (10°C) or higher,
the control will perform a Power On test before entering the freeze cycle.
The test consists of the following:
• Turn on the motor until it reaches home the next time.
• Turn on the water valve for 1/2 second.
• Tum on the heater for 1/2 second.
• Verify that the feeler arm was in the 'in' and then in the 'out' position.
• Verify that the motor was not in the home position and then in the home position.
• Verify that the motor does not remain on after being turned off.
• Proceed to the freeze cycle.
Note:The power on test will only add 1/2 second of water, which will not overflow the mold with a normal fill,
but may cause a small cube when the refrigerator is first started.
If the temperature is below 50°F (10°C), the control will power up normally.
Youtube Ge Ice Maker Repair
If in the home position, the control will enter the freeze cycle.
If the motor is not home, the control will enter the harvest cycle but bypass water fill to avoid overfilling the mold.
Service Diagnostics
During the first 15 seconds that power is first applied to the icemaker,
the Service Diagnostic Test mode may be entered.
The service mode is entered by pushing the feeler arm from the 'out' position to the 'in' position
and back again 3 times and only 3 times within 15 seconds.
Note: If the icemaker has already started a harvest cycle and the arm is moving,
it may be impossible to properly move the arm and enter the service mode without allowing it to reset and powering up again.
The service diagnostic mode consists of a harvest cycle followed by a water fill.
The harvest cycle is entered immediately, regardless of icemaker temperature or arm position.
Ge Refrigerator Ice Maker Repair Manual
While in the harvest cycle in the service mode, the heater will remain on for a minimum of 20 seconds.
The water fill cycle will initiate the first fill (5.1 seconds) without waiting for the mold to 'prechill'.
Only one water fill occurs during the service mode, whether the thermistor has reached 39.2°F (4°C) or not.
The icemaker will exit the service diagnostic test on its own and enter the normal freeze cycle.
If the ice maker won't do the manual harvest, replace it. Here's the replacement you need: http://www.repairclinic.com/PartDetail/Ice-Maker-Assembly/WR30X10093/1399596
Source: how do you cycle test the WR30X10093 icemaker
Ge Ice Maker Troubleshooting Manual
Sign in to follow this
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |